Department of Radiation Oncology, Princess Margaret Hospital, Toronto, ON, Canada.

Low-dose-rate prostate brachytherapy achieves a very high and effective intraprostatic dose. Implant quality parameters concentrate on the dose received by the prostate (D90, V100) but not that received by the periprostatic tissue. We calculated implant quality parameters, D90 and V100, for the magnetic resonance imaging (MRI)-defined prostate plus 2, 3, and 5 mm.

A total of 131 men with early-stage prostate cancer treated with iodine-125 brachytherapy represent all those treated with brachytherapy monotherapy in our institution in 2005. Postplan assessment was performed at 1 month using magnetic resonance (MR)-computed tomography (CT) fusion. The prostate V100 and D90 were calculated with 2-, 3-, and 5-mm margins. Results were compared with those in 8 patients with biopsy-proven local failure occurring in an experience of more than 1,100 implants.

Mean prostate V100 (SD) and D90 (SD) were 95.6% (4.1) and 117.2% (12.7). For prostate plus a 2-mm margin the D90 was 107.9% (14.3) and for a 3-mm margin 96.0 % (14.0). For prostate plus a 5-mm margin, the D90 was only 78.4% (11.0). The 8 patients experiencing local failure, despite adequate implants, had a lower mean V100 of 91.2% (SD, 2.8; p = 0.0008) and D90 of 103.7% (SD, 8.3; p = 0.002) and significantly inferior margin coverage.

Satisfactory coverage of a 2-mm and 3-mm periprostatic margin is obtained with the described planning approach. Coverage falls off significantly by 5 mm. The 8 patients who experienced local failure had significantly lower doses than the margin cohort. Although the V100 and D90 would be considered acceptable, the fall-off in margin coverage was observed by 3 mm.

Written by:
Crook J, Patil N, Ma C, McLean M, Borg J.   Are you the author?

Reference:
Int J Radiat Oncol Biol Phys. 2009 Oct 29. Epub ahead of print.
doi:10.1016/j.ijrobp.2009.06.040

PubMed Abstract
PMID:19879700

UroToday.com Prostate Cancer Section

Reader Comments

Please log-in or register in order to submit comments.

Powered by AkoComment!

 
User Rating: / 0
PoorBest


 

Bookmark and Share
< Prev   Next >

Member's Section

Login

Sign Up

Quick Search

Meet the Expert


All Experts



Featured Conference

Media and Publisher

Advertising Rates

Working with Industry

Case Studies
Sponsorship Opportunities

Prostate Cancer
Sponsored by