Reach urologists

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment - Abstract Show Comments PDF Print E-mail
  
Wednesday, 24 June 2009

Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, TX.

To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers.

Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated.

Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal.

The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

Written by:
Kudchadker RJ, Lee AK, Yu ZH, Johnson JL, Zhang L, Zhang Y, Amos RA, Nakanishi H, Ochiai A, Dong L.   Are you the author?

Reference:
Int J Radiat Oncol Biol Phys. 2009 May 7. Epub ahead of print.
doi:10.1016/j.ijrobp.2009.02.033

PubMed Abstract
PMID:19427750

UroToday.com Prostate Cancer Section

Reader Comments

Please log-in or register in order to submit comments.

Powered by AkoComment!

 
User Rating: / 0
PoorBest


 

Bookmark and Share
< Prev   Next >

Member's Section

Login

Sign Up

Quick Search

Meet the Expert


All Experts


Featured Conference

Media and Publisher

Advertising Rates
Reprints

Working with Industry

Case Studies
Sponsorship Opportunities

Craft of Urologic
Surgery Sponsored By