Reliability and Safety of Current Dynamic Sentinel Node Biopsy for Penile Carcinoma - Abstract Show Comments PDF Print E-mail
  
Friday, 05 October 2007
Department of Urology, The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.

Dynamic sentinel node biopsy (DSNB) has been performed at our department since 1994 to assess status of inguinal lymph nodes of clinically node-negative (cN0) patients with penile carcinoma. Over time, several modifications were made to reduce the false-negative rate and thus increase sensitivity. We compared the false-negative and complication rates of the current procedure, as performed at our institute since 2001, with the prior procedures

The patients who underwent DSNB for penile carcinoma in the period from 1994 until July 2004 were divided into two cohorts: cohort A: patients treated from 1994 until 2001; cohort B: patients treated from 2001 until 2004. Cohort A consisted of 92 patients, in whom 157 groins were explored. Cohort B consisted of 58 patients, with a total of 105 explored groins. Medians for follow-up in cohorts A and B were 83 (range: 24-130) and 30 (range: 24-49) mo, respectively. The false-negative and complication rates were determined in both cohorts.

In cohort A, 21 of 157 explored groins contained tumour-positive sentinel nodes, and five false-negative procedures were encountered, resulting in a false-negative rate of 19.2%. In cohort B, 20 of 105 explored groins contained tumour-positive sentinel nodes, and one procedure was false-negative. The false-negative rate was 4.8%. The rate of complications dropped from 10.2% in cohort A to 5.7% in cohort B. All complications were minor and transient

The false-negative and complication rates of DSNB have decreased since the procedure was modified. The current procedure has false-negative and complication rates of 4.8% and 5.7%, respectively. DSNB has matured into a reliable and safe method for assessing status of lymph nodes in cN0 penile carcinoma patients.

Written by
Leijte JA, Kroon BK, Valdés Olmos RA, Nieweg OE, Horenblas S.

Reference
Eur Urol. 2007 Jul;52(1):170-7. Epub 2007 Feb 7
doi:10.1016/j.eururo.2007.01.107

PubMed Abstract
PMID:17316967

UroToday.com Penis & Urethra Cancer Section

Reader Comments

Please log-in or register in order to submit comments.

Powered by AkoComment!

 
User Rating: / 1
PoorBest


 
Visitor Ratings:
No Affiliation:
5 (1 votes)


Bookmark and Share

Member's Section

Login

Sign Up

Quick Search

Meet the Expert


All Experts


Featured Conference

Media and Publisher

Advertising Rates
Reprints

Working with Industry

Case Studies
Sponsorship Opportunities

Penis & Urethra Cancer
Sponsored By